Eur. Phys. J. C manuscript No. (will be inserted by the editor)

arXiv:2207.09138v2 [physics.class-ph] 4 Aug 2022

A quest for the origin of the Sagnac eﬀect
Arunava Bhadra1,a, Souvik Ghose2,b, Biplab Raychaudhuri3,c
1 High Energy & Cosmic Ray Research Center, University of North Bengal, Siliguri 734013, India 2Department of Physics, Harish-Chandra Research Institute, Chhatnag Road, Jhunsi, Allahabad (Prayagraj), 211019, Uttar Pradesh, India. 3Department of Physics, Visva-Bharati University, Santiniketan, West Bengal, India, 731235

Received: date / Accepted: date

Abstract In the literature, there is no consensus on the origin of the relativistic Sagnac eﬀect, particularly from the standpoint of the rotating observer. The experiments of Wang et al. [1, 2] has, however, questioned the pivotal role of rotation of the platform in Sagnac eﬀect. Recently, the relative motion between the reﬂectors which force light to propagate along a closed path and the observer has been ascribed as the cause of the Sagnac eﬀect. Here, we propose a thought experiment on linear Sagnac eﬀect and explore another one proposed earlier to demonstrate that the origin of the Sagnac eﬀect is neither the rotation of frame aﬀecting clock synchronization nor the relative motion between the source and the observer; Sagnac eﬀect originates purely due to asymmetric position of the observer with respect to the light paths. Such a conclusion is validated by analysis of a gedanken Sagnac kind experiment involving rotation.
Keywords Sagnac eﬀect · STR · linear
1 Introduction
Sagnac eﬀect is the diﬀerence in phase (or time of arrivals) of two coherent light beams (originated from a single light beam) propagating along a rotating closed loop in opposite directions. The eﬀect was ﬁrst discovered by Sagnac [3, 4]. The eﬀect has been observed experimentally in a wide range of wavelength bands, from radio to x-rays as well as using matter waves [5–9]. The Sagnac eﬀect receives a lot of interest owing to its practical use in Global Positioning System [10],
ae-mail: aru_bhadra@yahoo.com be-mail: souvikghose@hri.res.in ce-mail: biplabphy@visva-bharati.ac.in

ﬁber optic gyroscope, ring laser gyroscope, etc. which are essentially Sagnac interferometers [11, 12]. The eﬀect also has applications in geodesy and seismology [13]. The Sagnac interferometer is nowadays used as a tool in civil aviation [11–13], to test gravitation theories [14–18], to examine quantum properties [19].
The Sagnac eﬀect, which is generally considered as one of the basic experimental eﬀects of STR, is a ﬁrst-order kinematic eﬀect in v/c. Sagnac, however, proposed the experiment in support of his ether model and explained the eﬀect without using relativity theory. Since then numerous studies have been conducted on the interpretation of the eﬀect, particularly from the viewpoint of the (co-)rotating observer [20] which include standard special relativistic description [21], general relativistic description [22–26], synchronization issues in rotating frame [27–29], violation of relativity in rotating frame [4, 30] etc. Most of such approaches yield the correct magnitude of the Sagnac eﬀect despite their vast diﬀerences in the physical basis of the eﬀect.
In the early part of the present century a couple of experimental studies have demonstrated that a Sagnac like eﬀect, which the authors called the generalized Sagnac eﬀect, occurs in a light waveguide loop consisting of both linearly and circularly moving segments [1, 2]. Interestingly, it was found that both the segments contribute to the generalized Sagnac eﬀect which implies that rotational motion is not essential for the Sagnac eﬀect. Sagnac type gedanken experiment with linear motion (“Linear Sagnac Eﬀect”(LSE)) was probably ﬁrst proposed by Ghosal et al., [31] and they found that the Sagnac delay in the linear case perfectly matches that of the original Sagnac eﬀect when the re-

2

B Fig. 1 Linear Sagnac

O

Q D1 v D2

A

sult is written in terms of the linear velocity without using the area enclosed by the circuit.
Noting the experimental ﬁndings of Wang et. al. [1, 2] recently, Tartaglia and Ruggiero [32] have proposed a Sagnac-like thought experiment consisting of a rectangular closed light path in which an observer is moving along a side of the rectangle with a linear velocity. They concluded that Sagnac eﬀect occurs on the closed path of light in space and when a relative motion exists between the observer and the physical device (mirrors) restricting light to propagate along a closed path.
An important point to be noted at this stage is that in the original Sagnac experiment, both the observer and the physical system employed to move light along the circular path rotate with the same angular velocity. Hence, the existence of a relative motion between the observer and the mirrors [32] cannot be the root cause of the Sagnac eﬀect. In this work, we argue that the cause of the Sagnac or generalized Sagnac eﬀect is the non-mid point measurement of arrival times of the counter-propagating light rays (causing unequal path lengths traversed by the light rays in reaching the interferometer), both in the lab frame and the Interferometer frame.

2 A Thought Experiment
Let us consider a simple gadanken experiment where two light beams, originating from a single one, using beam splitter, are allowed to propagate in two opposite directions OA and OB (ﬁg. 1) along closed linear paths in the lab frame. For convenience, we choose our coordinate system in such a way that the points A, O, B are on the x-axis. O is the midpoint of AB so that OA = OB = L. We shall take diﬀerent situations involving the dynamics of the detector and the reﬂecting mirrors which are employed to restrict the motion of the light rays in closed paths. The coordinates of the frame of reference attached with the detector/interferometer are denoted with primes as superscript.
In the ﬁrst case let us consider the detector (I), which was initially (i.e. at the time light rays start propagating along OA and OB) at point Q where OQ = q, moves with a linear constant velocity v with respect to

the lab frame along positive x direction. The mirrors (reﬂectors), which are initially at A and B, also move with the same velocity v along the same direction so that no relative velocity exists between the observer attached to the interferometer and the mirrors, as in the original Sagnac eﬀect. In the detector frame, the diﬀerence in arrival of time between the lights traveling the path O′A′O′B′Q′ and O′B′O′A′Q′ will be

∆t

=

2q γc

,

(1)

where γ ≡ 1/ 1 − v2/c2 is the Lorentz factor. When q=0, i.e. when the detector at the mid point of the light path O′A′O′B′Q′ (O′A′ = O′B′) there will be no Sagnac eﬀect. In general, for non-zero q (nonmid point measurement) there will be a delay in arrival times of two oppositely moving light rays. Such a delay, however, does not depend on the velocity of the observer. The same conclusion can be reached in the Lab (un-primed) frame also.
Next, we consider the detector is moving, but the mirrors are at rest in the Lab frame. This situation is essentially similar to the rectangular closed path case considered in [32]. Here, the trajectory for the light rays that starts moving initially towards the negative x-axis is OBOAD1 , where D1 is the position of the detector when the light ray reaches the detector. The total time taken by the stated light rays to reach the detector is

∆t−

=

4L − q c+v

.

(2)

For reaching the detector at D, the path of the light rays that propagate towards positive x-axis initially is OAOBOD2 and the total time taken in the process is

∆t+

=

4L − q c−v

.

(3)

The time diﬀerence of arrival of two opposite directed light rays at the detector is

∆t

=

∆t+

− ∆t−

=

8Lv c2

+ 2qc − v2

.

(4)

Note that the measurement will be made by the moving observer. Hence, applying the Lorentz transformations the time delay to be measured by the moving observer, as inferred from the Lab frame will be

∆tobs

=

8Lv γ(c2

+ −

2qc v2)

.

(5)

When q = 0, one gets the usual generalized linear Sagnac (like) eﬀect. On the other hand, if q = −4Lv/c,

3

O P ω D1
D2
Fig. 2 Original Sagnac Modiﬁed

there will be no Sagnac delay, implying that the measurements of the arrival times are made exactly at point O which is the mid-point of the light trajectories (between the mirrors).
In the primed frame, the detector is at rest. The mirrors are moving with a velocity v towards the negative x-direction. The light path for the rays that starts moving initially towards the negative x-axis is O′B1′ OA′2O′, where B1′ is the position of the mirror when light reached the reﬂector, which was initially at B. At that moment, the mirror A was at A′1 position. After reﬂecting by the mirror at B1′ the light ray will move towards positive x-axis direction and reach the reﬂector A at A′2 position. Since O′B1′ not equals to O′A′2, O′ is not the mid-point of the light path. The detector bound observer will ﬁnd that the lengths contracted according to STR. Accordingly, in the primed frame the diﬀerence in time of arrival of two opposite directed light rays at the detector will be

∆t′obs

=

8Lv γ(c2

+ −

2qc v2)

.

(6)

which is exactly what the Lab frame is interpreted. The diﬀerence in arrival times of the two oppositely moving light beams in the lab frame and the frame attached to the detector are, thus, simply connected by special relativistic time dilation as expected.

3 On the original Sagnac experiment
Now ﬁnally let us consider the original Sagnac experiment as displayed in ﬁg. 2. Here two light rays start to move, say at time to, from the point O in opposite directions, clockwise and anti-clockwise along the perimeter of a circle of radius r. At that instant, an observer with

an interferometer is placed at P , where the arc OP = p. The whole set up is placed on a rotating disk/platform having angular velocity ω (in lab frame) with the center of the disk coincides with that of the circular path of the light rays.
In the Lab frame, the diﬀerence in arrival time of clockwise and anticlockwise light rays in the interferometer will be

∆t

=

4πrv + 2pc c2 − v2

.

(7)

where v = rΩ, Ω being the angular velocity of the rotating platform. Translating the above time delay to the observation by the rotating observer is not straightforward. Some scientists suggest that relativistic kinematic transformations are valid not only between inertial frames with uniform relative velocity but also for reference frames undergoing acceleration [33]. Following (i.e. essentially assuming that the Lorentz transformations hold between the Lab frame and the rotating observer) [33], the diﬀerence in arrival time of clockwise and anticlockwise light rays in the interferometer of the rotating observer will be

∆t′

=

4πrv γ(c2

+ −

2pc v2)

.

(8)

The above expression, which is obtained from Eq. 7 taking in to account the time dilation eﬀect, generalizes the one given in [33] for arbitrary initial position of the observer. Again for p=0, one gets the usual expression for the Sagnac delay. For p = −2πrv/c, i.e. when the measurements are made at the point of initiation of the journey there will be no Sagnac delay.
Several researchers prefer to explain the Sagnac effect in the purview of general theory of relativity (GR). Langevin ﬁrst explained the Sagnac eﬀect from GR consideration. The basic approach in GR based explanation is to compute the diﬀerence of propagation times in reaching the detector between counter-propagating waves in the space-time metric that eﬀectively represents the frame of reference attending rotation. In the laboratory frame the space-time interval in cylindrical coordinates (t, r, φ, z) is given by

ds2 = c2dt2 − dr2 − r2dφ2 − dz2

(9)

Now when the platform starts rotating with uniform rotating velocity Ω along z-axis, the space time interval associated with the platform (t′ = t, r′ = r, φ′ = φ + Ωt, z′ = z) [23]

ds2 = (c2−r2Ω2)dt2−2Ωr2dφdt−dr2−r2dφ2−dz2 (10)

4

The space time curvature vanishes for the above space time metric implying that there is no gravitational ﬁeld associated with the metric. For the circular (dr = 0) light trajectory (ds = 0) at rφ plane the eq. (10) gives

dt′cl,acl

=

±rdφ c ∓ rΩ

(11)

The subscript cl and acl denote clockwise and anticlockwise respectively. The total propagation time for clockwise light rays to reach the observer

∆t′cl =

2π −p

dt′cl

=

2πr c−

+p rΩ

(12)

and that for anticlockwise light rays

∆t′acl =

−2π −p

dt′cl

=

2πr − p c + rΩ

(13)

Hence the diﬀerence in arrival times between the counter-propagating light rays is exactly the same to eq. (8) as obtained in the Lab frame. However, one may notice that the above derivation does not give the time dilation eﬀect. In his review article Post [6] argued that the time coordinate should transform as t′ = γt while switching over from Lab frame to stationary frame which leads to the time dilation eﬀect.
A worthwhile point to be noted that the metric given in eq. (10) is derived from the Lab frame space time metric; it is the metric of the rotating frame according to a Lab frame observer. Though mathematically it is ﬁne but the physical understanding of the eﬀect from the standpoint of an observer attending the rotation remains diﬃcult. When p = 0, i.e. the observer at the point of splitting remains on that point in the rotating frame, why clockwise and anti-clockwise light will take diﬀerent times to reach the observer?
To understand the point mentioned above let us ﬁrst consider a Sagnac like thought experiment involving rectangular trajectories of light rays in the Lab (inertial) frame as discussed in [32]. Say, ABCD is a square/rectangle in an inertial frame S. Using a beam splitter, a light signal is directed to move along the paths ABCDA and ADCBA (reﬂectors placed at points A, B, C, D). Both the light rays initially start their motion from the same point A at the same time. They are expected to meet at A, where an interferometer is placed, at the same instant. We allow the interferometer, which was initially at point A at the time of the two light beams started their journey along ABCDA and ADCBA, to move along AB with a constant velocity v. For simplicity of the calculation the

D

C

D

C

AI

B

AI

B

Fig. 3 As seen from Lab frame: (a) clockwise (b) countercolckwise

length of the sides and the velocity v are so chosen that both the clockwise and anticlockwise light beams reach the interferometer before it (interferometer) crosses the B point i.e. AB/v > (3AB + 2BC)/c which implies v < c/(3 + 2ξ) where ξ = BC/AB.

3.1 From the Lab frame

We shall now explore what will be the observations of the lab frame and the observer attached with the interferometer. From the viewpoint of the lab frame, the light rays that travel along ADCBI path will reach the interferometer (I) earlier than that propagate along ABCDAI (please refer to ﬁgure 1(a)). Denoting the length of the sides AB=CD=p and BC=DA=q, the difference in arrival times of the anticlockwise and clockwise moving light beams is

∆ξ

=

4(p + q)v c2 − v2

(14)

which is similar to the Sagnac eﬀect; the only diﬀerence is that in the Sagnac eﬀect the perimeter of a circle occurs instead of a rectangle, as the light paths in the Sagnac experiment are circular [32].
Now we consider the viewpoint of the observer O′ attached with the interferometer. For O′ the points A, B, C and D are moving with a constant velocity ˘v. In this frame the length AB and DC will be contracted following the Lorentz contraction formula whereas the length BC and AD will remain unaltered. The light trajectories for clockwise and anticlockwise motion as will perceive by O′ are shown in ﬁg.(4).
Therefore, the arrival time diﬀerence of the anticlockwise and clockwise moving light beams as be viewed by O′ is:

∆ξ′

=

4(p + q)v γ(c2 − v2)

(15)

Here also the diﬀerence in arrival times of the anticlockwise and clockwise moving light beams in the lab frame and the frame attached to the detector are

5

D1 D

C1 C

D1 D

C1 C

A,I

B1 B

A1 A,I

B1 B

Fig. 4 As seen from observer frame: (a) clockwise (b) counterclockwise

simply connected by special relativistic time dilation as expected. The most striking point of the above Sagnac kind thought experiment involving rectangular trajectories (in Lab frame) is that in the frame attached with the interferometer, the geometries of the travelling paths for the clockwise and the anticlockwise light rays are not rectangular; they trace two diﬀerent unequal paths while moving from the point A to the Interferometer as shown in ﬁg. (4).
So a relevant question is whether in original Sagnac experiment the light trajectories are circular in the frame attending the rotation? In the light of the so called Ehrenfest paradox, a circle in the Lab frame is unlikely to be perceived as a circle by the observer attending the rotation.

4 Discussion
We conclude that the origin of the Sagnac Delay or the phase diﬀerence in Sagnac or Sagnac-like experiments is the non-mid-point measurement of arrival times of counter-propagating waves leading to unequal path lengths traversed by the oppositely directed light rays in reaching the interferometer. It does not depend exclusively on the rotation, as correctly pointed out in [32]. The synchronization issues in the rotating frame cannot be the cause as we have seen that zero Sagnac delay is possible in the Sagnac experiment depending on the arrival times measurement location. The relative motion between the detector and the reﬂectors is also not the reason for the Sagnac delay.
In the lab frame, the non-mid point position of the observer and thereby inequality of the path lengths of the two oppositely directed light rays in the Sagnac experiment is straightforward. However, from the standpoint of the rotating observer, the issue is quite diﬃcult to understand.
So we have considered a linear version of the Sagnac experiment, where, because of the linear constant relative speed of the interferometer and mirrors, one can easily deduce the light paths in the interferometer frame. In the frame attached with the interferometer,

the oppositely directed light rays trace unequal paths while moving from the point O to the interferometer, if the observation is conducted any other point than O. So from both the concerned frames, the underlying reason for the observed phase diﬀerence is the same, the non-mid point observation. If the detector has zero velocity but the measurement is made at any non-midpoint, there will be a Sagnac kind time delay but obviously, it (delay) will not depend on the velocity. Such a linear version is not exactly the same as the Sagnac experiment. In the proposed linear case there is a relative velocity between the detector and the reﬂectors and the distance between the detector and the reﬂectors continuously alters, unlike the Sagnac experiment where such distances always remain the same, at least in the lab frame. The gedanken original Sagnac kind experiment involving rotation also validates the nonmid-point measurement as the root cause of the Sagnac eﬀect in the Lab frame.
An interesting question is whether a time dilation eﬀect will be present in a Sagnac eﬀect for the rotating observer. The Lorentz γ-factor occurs for linear constant relative speed between two inertial frames. For rotating motion, there may be some modiﬁcation in that factor [31, 34]. This has been discussed in detail in view of the Ehrenfest paradox using LSE in Ref. [31, 35]. The proposed thought experiment cannot say anything about the appearance of the Lorentz γ-factor in a rotating frame. An experimental determination of this factor would be of considerable interest.
References
1. R. Wang, Y. Zheng, A. Yao, D. Langley, Physics Letters A 312(1-2), 7 (2003)
2. R. Wang, Y. Zheng, A. Yao, Physical review letters 93(14), 143901 (2004)
3. G. Sagnac, Comptes Rendus de l’Academie des Sciences 157, 1410 (1913)
4. G. Sagnac, J. Phys. Theor. Appl. 4(1), 177 (1914) 5. S. Vavilov, Experimental grounds of the theory of
relativity") Sobranie Sochineni&ibreve 4 (1956) 6. E.J. Post, Reviews of Modern Physics 39(2), 475
(1967) 7. U. Frankfurt, A. Frank, M. Nauka pp. 76–112
(1972) 8. F. Hasselbach, M. Nicklaus, Physical Review A
48(1), 143 (1993) 9. G. Pascoli, Comptes Rendus Physique 18(9-10),
563 (2017) 10. N. Ashby, in Relativity in rotating frames
(Springer, 2004), pp. 11–28 11. R. Rodloﬀ, Laser und Optoelektronik 2, 131 (1985)

6
12. K.U. Schreiber, J.P.R. Wells, Review of Scientiﬁc Instruments 84(4), 041101 (2013)
13. A. Velikoseltsev, U. Schreiber, T. Klügel, S. Voigt, R. Graham, Gyroscopy and Navigation 1(4), 291 (2010)
14. M.O. Scully, M.S. Zubairy, M. Haugan, Physical Review A 24(4), 2009 (1981)
15. L.I. Schiﬀ, Proceedings of the National Academy of Sciences of the United States of America 46(6), 871 (1960)
16. F. Bosi, G. Cella, A. Di Virgilio, A. Ortolan, A. Porzio, S. Solimeno, M. Cerdonio, J. Zendri, M. Allegrini, J. Belﬁ, et al., Physical Review D 84(12), 122002 (2011)
17. A. Tartaglia, M.L. Ruggiero, arXiv preprint grqc/0401005 (2004)
18. A. Bhadra, T. Nayak, K. Nandi, Physics Letters A 295(1), 1 (2002). DOI https://doi.org/10.1016/ S0375-9601(02)00132-9
19. J.M. Ashby, P.D. Schwarz, M. Schlosshauer, Physical Review A 94(1), 012102 (2016)
20. G.B. Malykin, Physics-Uspekhi 40(3), 317 (1997) 21. M. Laue, Annalen der Physik 367(13), 448 (1920) 22. P. Langevin, Compt. rend 173, 831 (1921) 23. L.D. Landau, L. Landau, E. Lifshitz, The Classical
Theory of Fields: Volume 2, vol. 2 (ButterworthHeinemann, 1975) 24. M.A. Tonnelat, The principles of electromagnetic theory and of relativity (Springer Science & Business Media, 2012) 25. A. Ashtekar, A. Magnon, Journal of Mathematical Physics 16(2), 341 (1975) 26. E. Benedetto, F. Feleppa, I. Licata, H. Moradpour, C. Corda, The European Physical Journal C 79(3), 1 (2019) 27. F. Selleri, Foundations of Physics 27(11), 1527 (1997) 28. F. Goy, F. Selleri, Foundations of Physics Letters 10(1), 17 (1997) 29. J. Croca, F. Selleri, Nuovo Cimento B Serie 114(4), 447 (1999) 30. A. Kelly, Time and the Speed of Light: A New Interpretation (Institution of Engineers of Ireland, 1995) 31. S. Ghosal, B. Raychaudhuri, A.K. Chowdhury, M. Sarker, Foundations of Physics 33(6), 981 (2003) 32. A. Tartaglia, M.L. Ruggiero, American Journal of Physics 83(5), 427 (2015) 33. G.B. Malykin, Physics-Uspekhi 43, 1229 (2000) 34. F. Selleri, Foundations of Physics 26(5), 641 (1996) 35. B. Raychaudhuri, Conceptual questions in relativistic sagnac eﬀect and related issues. Ph.D. thesis,

North Bengal University, India (2005)